Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: Industrial Relay/UniversalDescription: AF12Z 3Pole Contactor, 9A, 5.5kW, 60V dc Coil85401+$486.220010+$473.536050+$463.8116100+$460.4292200+$457.8924500+$454.51001000+$452.39602000+$450.2820
-
Category: Industrial Relay/UniversalDescription: AF16Z 4Pole Contactor, 30A, 7.5kW, 20 to 60V dc, 24 to 60V ac Coil57971+$607.087610+$585.786350+$583.1236100+$580.4610150+$576.2007250+$572.4730500+$568.74521000+$564.4850
-
Category: Industrial Relay/UniversalDescription: ESB The series of solenoid valve contactors can be used for controlling loads with a large number of operations, such as pumps, heating or ventilation systems. Additional auxiliary contacts can be installed on the contactors, such as stock number 445-8093. Except for ESB20 type, terminal covers can be installed - ESB 24 type and higher versions. Note that when installing contactors side by side, gaskets (stock number 478-0817) should be installed between each pair of contactors. ###ABB Attachment # # # Note: These contacts cannot be used with ESB20 type installed contactors and can only be used with higher types such as ESB24 type installed contactors51731+$333.701310+$324.996050+$318.3220100+$316.0006200+$314.2595500+$311.93811000+$310.48732000+$309.0364
-
Category: Industrial Relay/UniversalDescription: ESB The series of solenoid valve contactors can be used for controlling loads with a large number of operations, such as pumps, heating or ventilation systems. Additional auxiliary contacts can be installed on the contactors, such as stock number 445-8093. Except for ESB20 type, terminal covers can be installed - ESB 24 type and higher versions. Note that when installing contactors side by side, gaskets (stock number 478-0817) should be installed between each pair of contactors. ###ABB Attachment # # # Note: These contacts cannot be used with ESB20 type installed contactors and can only be used with higher types such as ESB24 type installed contactors32841+$397.433110+$387.065350+$379.1166100+$376.3519200+$374.2783500+$371.51361000+$369.78562000+$368.0576
-
Category: Industrial Relay/UniversalDescription: ABB A9-30-10-110V-50Hz Contactor, 690VAC, 3Pole, 3PST-NO, Panel, 25A, 110V52171+$286.024610+$278.563050+$272.8425100+$270.8528200+$269.3605500+$267.37081000+$266.12722000+$264.8836
-
Category: Industrial Relay/UniversalDescription: AF16 4Pole Contactor, 30A, 7.5kW, 100 - 250V AC-DC Coil39721+$540.374710+$526.277950+$515.4704100+$511.7113200+$508.8920500+$505.13281000+$502.78342000+$500.4339
-
Category: Industrial Relay/UniversalDescription: AF16 4Pole Contactor, 30A, 7.5kW, 250 - 500V AC-DC Coil12111+$540.374710+$526.277950+$515.4704100+$511.7113200+$508.8920500+$505.13281000+$502.78342000+$500.4339
-
Category: Industrial Relay/UniversalDescription: AF16 4Pole Contactor, 30A, 7.5kW, 48- 130V AC-DC Coil52191+$642.793610+$620.239450+$617.4201100+$614.6009150+$610.0900250+$606.1431500+$602.19611000+$597.6852
-
Category: Industrial Relay/UniversalDescription: AF09Z 3Pole Contactor, 7A, 4kW, 60VDC Coil97051+$396.213010+$385.877050+$377.9527100+$375.1964200+$373.1292500+$370.37301000+$368.65032000+$366.9276
-
Category: Industrial Relay/UniversalDescription: AF38 3Pole Contactor, 24A, 18.5kW, 100 - 250V AC-DC Coil40131+$749.912510+$723.599850+$720.3107100+$717.0216150+$711.7591250+$707.1544500+$702.54961000+$697.2871
-
Category: Industrial Relay/UniversalDescription: ABB AF09Z-22-00-21 Contactor, 60V, 4Pole, 2NO / 2NC, DIN Rail, 25A, 60V54031+$486.220010+$473.536050+$463.8116100+$460.4292200+$457.8924500+$454.51001000+$452.39602000+$450.2820
-
Category: Industrial Relay/UniversalDescription: AF09 4Pole Contactor, 25A, 4kW, 100 - 250V AC-DC Coil35161+$355.430510+$346.158450+$339.0498100+$336.5772200+$334.7228500+$332.25031000+$330.70492000+$329.1596
-
Category: Industrial Relay/UniversalDescription: AF09 3Pole Contactor, 7A, 4kW, 130VDC Coil99701+$370.975110+$361.297450+$353.8779100+$351.2972200+$349.3617500+$346.78101000+$345.16812000+$343.5552
-
Category: Industrial Relay/UniversalDescription: AF12 3Pole Contactor, 12.5A, 7.5kW@ 600V, 100 - 250V AC-DC Coil18531+$285.834810+$278.378250+$272.6615100+$270.6731200+$269.1818500+$267.19341000+$265.95062000+$264.7079
-
Category: Industrial Relay/UniversalDescription: AF Series contactors, the 4-pole ABB 4-pole contactor series is suitable for controlling power circuits up to 690 V AC and 440 V DC. Built in surge protection, no need for additional surge suppressors to manage large control voltage changes. One coil can be used for different control voltages and can be used worldwide without changing the coil. ABB AF series31711+$471.607010+$459.304250+$449.8720100+$446.5913200+$444.1307500+$440.85001000+$438.79952000+$436.7490
-
Category: Industrial Relay/UniversalDescription: AC2;AC3 Rated coil power: 3.5VA, 3.5W (closed and held) Switching times: 14 to 26/16/16 to 40ms # # # ABB MS116 series37121+$137.200810+$133.621650+$130.8776100+$129.9231200+$129.2073500+$128.25291000+$127.65642000+$127.0598
-
Category: Industrial Relay/UniversalDescription: CONTACTOR, 5.5kW, 12A; Operating Voltage: 110VAC; Switching Power AC3: 5.5kW; Switching Current AC1: 27A; Switching C...12721+$398.951110+$388.543750+$380.5647100+$377.7893200+$375.7079500+$372.93261000+$371.19802000+$369.4634
-
Category: Industrial Relay/UniversalDescription: AF The series contactor, 3-pole AF contactor, is an AC/DC operated AF09-AF38 contactor that includes an electronic coil interface and can accept a wide range of control voltages Ucmin Ucmax. Only 4 coils contain control voltage of 24 → 500 V AC or 20 → 500 V DC. The AF. Z contactor is equipped with a Z coil type, allowing direct control through 24 V DC, 500 mA PLC output, which can reduce coil consumption. The AF. Z contactor can withstand short-term drops and voltage interruptions (in accordance with SEMI F47-0706). The AF40-AF96 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are designed with a block shape of 3 main poles. The AF116-AF140 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC, while the AF146 AF190-AF370 contactor is mainly used to control 3-phase motors and power circuits up to 1000 V AC. These contactors are designed in a block shape with 3 main poles. The AF contactor has built-in surge protection and does not require any additional surge suppressors. Standard IEC 60947-1/60947-4-7 and EN 60947-1/60947-4-1. ABB AF series53121+$4065.613210+$4028.653125+$4010.173050+$3991.6930100+$3973.2129150+$3954.7328250+$3936.2528500+$3917.7727
-
Category: Industrial Relay/UniversalDescription: Electronic overload relay with shear pin protection standard and lockout version providing DMPR, featuring the following features: power supply voltage of 115-230V AC tripping and alarm contacts, suitable for up to 200A load current, power warning and tripping indication, automatic/manual/local/remote reset testing equipment, independent adjustable start delay, used for high inertia loads, independent adjustable running time, adjustable reset delay, accepting thermistor input (OVE temperature), single-phase locked rotor (shear pin protection) during startup suppression, ABB # # #57791+$2977.132410+$2950.067625+$2936.535150+$2923.0027100+$2909.4703150+$2895.9379250+$2882.4055500+$2868.8730
-
Category: Industrial Relay/UniversalDescription: AF The series contactor, 3-pole AF contactor, is an AC/DC operated AF09-AF38 contactor that includes an electronic coil interface and can accept a wide range of control voltages Ucmin Ucmax. Only 4 coils contain control voltage of 24 → 500 V AC or 20 → 500 V DC. The AF. Z contactor is equipped with a Z coil type, allowing direct control through 24 V DC, 500 mA PLC output, which can reduce coil consumption. The AF. Z contactor can withstand short-term drops and voltage interruptions (in accordance with SEMI F47-0706). The AF40-AF96 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are designed with a block shape of 3 main poles. The AF116-AF140 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC, while the AF146 AF190-AF370 contactor is mainly used to control 3-phase motors and power circuits up to 1000 V AC. These contactors are designed in a block shape with 3 main poles. The AF contactor has built-in surge protection and does not require any additional surge suppressors. Standard IEC 60947-1/60947-4-7 and EN 60947-1/60947-4-1. ABB AF series14411+$4746.551710+$4703.401225+$4681.826050+$4660.2508100+$4638.6755150+$4617.1003250+$4595.5251500+$4573.9498
-
Category: Industrial Relay/UniversalDescription: AF Series contactors, the 4-pole ABB 4-pole contactor series is suitable for controlling power circuits up to 690 V AC and 440 V DC. Built in surge protection, no need for additional surge suppressors to manage large control voltage changes. One coil can be used for different control voltages and can be used worldwide without changing the coil. ABB AF series41671+$1422.687210+$1409.753725+$1403.286950+$1396.8202100+$1390.3534150+$1383.8866250+$1377.4199500+$1370.9531
-
Category: Industrial Relay/UniversalDescription: CM-SRS Current monitoring, single-phase AC/DC, according to configuration, current monitoring relays CM-SRS 1 and CM-SRS. 2 can be used in single-phase AC and/or DC systems to monitor overcurrent or undercurrent. The current to be monitored (measured value) will be applied to terminal blocks B1/B2/B3-C. The device operates based on the open circuit principle. If the measured value exceeds the response and drops below the adjusted threshold, the output relay will be powered on: CM-ESS. 1 will be powered on immediately, and CM-ESS. 2 will be powered on after the set trigger delay TV. Monitoring DC and AC currents: CM-SRS.x1: 3mA-1A and CM-SRS.x2: 0.3-15A Effective value measurement principle One device includes 3 measurement ranges configurable overcurrent or undercurrent monitoring Hysteresis adjustable range: 3-30% disconnect delay TV adjustable range: 0.1-30s CM-SRS.1:1 c/o contacts CM-SRS.2:2 c/o contacts 22.5mm width 3 LED status indication # # ABB CM series12251+$1985.651810+$1967.600425+$1958.574750+$1949.5490100+$1940.5234150+$1931.4977250+$1922.4720500+$1913.4463
-
Category: Industrial Relay/UniversalDescription: CM-SRS Current monitoring, single-phase AC/DC, according to configuration, current monitoring relays CM-SRS 1 and CM-SRS. 2 can be used in single-phase AC and/or DC systems to monitor overcurrent or undercurrent. The current to be monitored (measured value) will be applied to terminal blocks B1/B2/B3-C. The device operates based on the open circuit principle. If the measured value exceeds the response and drops below the adjusted threshold, the output relay will be powered on: CM-ESS. 1 will be powered on immediately, and CM-ESS. 2 will be powered on after the set trigger delay TV. Monitoring DC and AC currents: CM-SRS.x1: 3mA-1A and CM-SRS.x2: 0.3-15A Effective value measurement principle One device includes 3 measurement ranges configurable overcurrent or undercurrent monitoring Hysteresis adjustable range: 3-30% disconnect delay TV adjustable range: 0.1-30s CM-SRS.1:1 c/o contacts CM-SRS.2:2 c/o contacts 22.5mm width 3 LED status indication # # ABB CM series38651+$1751.666410+$1735.742225+$1727.780050+$1719.8179100+$1711.8558150+$1703.8937250+$1695.9316500+$1687.9694
-
Category: Industrial Relay/UniversalDescription: CM-MPS x3 The multifunctional three-phase monitoring relay CM-MPSx3 is a monitoring relay used for three-phase power supply. They can monitor phase parameters such as phase sequence, phase faults, overvoltage and undervoltage, as well as phase imbalance. CM-MPS.23 can also perform incomplete neutral line monitoring. The thresholds for overvoltage, undervoltage, and phase imbalance can be adjusted. CM-MPS.23 is also suitable for monitoring single-phase power supplies. Therefore, these three external wires (L1, L2, L3) must be jumper and connected as a single wire. The phase sequence monitoring must be disabled, and the threshold for phase imbalance must be set to the maximum value (25%). The monitoring of phase sequence (can be turned off), phase faults, overvoltage and undervoltage, and phase imbalance of three-phase power supply can be configured with automatic phase sequence correction. Incomplete neutral line monitoring can be performed through CM-MPS.23. CM-MPS.23 can also be used to monitor single-phase power supply. The threshold values for phase imbalance, overvoltage and undervoltage can be adjusted as absolute values. The disconnection delay can be adjusted or turned off through logarithmic scale. The disconnection delay can be selected as on delay or off delay. It is powered by the measurement circuit. The true effective value measurement principle is 1x2 or 2x1 c/o (single pole double throw). The contact (can be configured) has 3 LEDs for status indication. ABB CM series97331+$1251.350110+$1239.974225+$1234.286250+$1228.5983100+$1222.9103150+$1217.2224250+$1211.5344500+$1205.8465
-
Category: Industrial Relay/UniversalDescription: CM-PSS Three phase monitoring relay CM-PSS.x1 is a monitoring relay used for three-phase power supply. They can monitor phase parameters, phase sequence, phase faults, overvoltage and undervoltage. The thresholds for overvoltage and undervoltage are fixed. The phase sequence (can be turned off), phase faults, monitoring of overvoltage and undervoltage of three-phase power supply. The fixed threshold for overvoltage and undervoltage disconnection delay can be adjusted or turned off through logarithmic scale. The disconnection delay can be selected as on delay or off delay. It is powered by the measurement circuit. The true effective value measurement principle is 2 c/o (single pole double throw) contacts, 3 LEDs for status indication. ABB CM series54101+$1767.128010+$1751.063225+$1743.030850+$1734.9984100+$1726.9660150+$1718.9336250+$1710.9012500+$1702.8688
-
Category: Industrial Relay/UniversalDescription: CM-SFS Current monitoring relay, 1-bit AC/DC current window monitoring relay CM-SFS. 2 can be used to simultaneously monitor overcurrent and undercurrent in single-phase AC and/or DC systems. Two closed/open contacts can be configured to work together (bipolar conversion) or independently (2x unipolar conversion) for overcurrent and/or undercurrent conditions... The current to be monitored (measured value) will be applied to terminal block B1/B2/B3-C. Can be configured with open or closed circuit principle and adjustable on/off delay monitoring for DC and AC currents: CM-SFS. 21:3mA-1A and CM-SFS. 22:0.3-15A. Effective value measurement principle: One device includes 3 measurement ranges for overcurrent and/or undercurrent monitoring. Can be configured with on/off delay and open or closed circuit principle. Can be configured with locking function, adjustable threshold for Imin and Imax. 5% fixed lag startup delay. TS adjustable range: 0; 0.1-30s disconnect delay TV adjustable range: 0; 0.1-30s 1x2 closed/open contacts (universal signal) or 2x1 closed/open contacts (Imin and Imax use independent signals) 22.5mm width 3 LED status indication # # # ABB CM series22651+$1312.312110+$1300.382025+$1294.416950+$1288.4519100+$1282.4868150+$1276.5218250+$1270.5567500+$1264.5917
-
Category: Industrial Relay/UniversalDescription: ABB A26-30-10-110V-50Hz Contactor, 690VAC, 3Pole, 3PST-NO, Panel, 45A, 110V12171+$1061.627310+$1024.377250+$1019.7209100+$1015.0647150+$1007.6147250+$1001.0959500+$994.57711000+$987.1271
-
Category: Industrial Relay/UniversalDescription: AF The series contactor, 3-pole AF contactor, is an AC/DC operated AF09-AF38 contactor that includes an electronic coil interface and can accept a wide range of control voltages Ucmin Ucmax. Only 4 coils contain control voltage of 24 → 500 V AC or 20 → 500 V DC. The AF. Z contactor is equipped with a Z coil type, allowing direct control through 24 V DC, 500 mA PLC output, which can reduce coil consumption. The AF. Z contactor can withstand short-term drops and voltage interruptions (in accordance with SEMI F47-0706). The AF40-AF96 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are designed with a block shape of 3 main poles. The AF116-AF140 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC, while the AF146 AF190-AF370 contactor is mainly used to control 3-phase motors and power circuits up to 1000 V AC. These contactors are designed in a block shape with 3 main poles. The AF contactor has built-in surge protection and does not require any additional surge suppressors. Standard IEC 60947-1/60947-4-7 and EN 60947-1/60947-4-1. ABB AF series28751+$5177.911210+$5130.839325+$5107.303350+$5083.7674100+$5060.2314150+$5036.6954250+$5013.1595500+$4989.6235
-
Category: Industrial Relay/UniversalDescription: AF The series contactor, 3-pole AF contactor, is an AC/DC operated AF09-AF38 contactor that includes an electronic coil interface and can accept a wide range of control voltages Ucmin Ucmax. Only 4 coils contain control voltage of 24 → 500 V AC or 20 → 500 V DC. The AF. Z contactor is equipped with a Z coil type, allowing direct control through 24 V DC, 500 mA PLC output, which can reduce coil consumption. The AF. Z contactor can withstand short-term drops and voltage interruptions (in accordance with SEMI F47-0706). The AF40-AF96 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are designed with a block shape of 3 main poles. The AF116-AF140 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC, while the AF146 AF190-AF370 contactor is mainly used to control 3-phase motors and power circuits up to 1000 V AC. These contactors are designed in a block shape with 3 main poles. The AF contactor has built-in surge protection and does not require any additional surge suppressors. Standard IEC 60947-1/60947-4-7 and EN 60947-1/60947-4-1. ABB AF series20391+$1769.907710+$1753.817625+$1745.772650+$1737.7276100+$1729.6825150+$1721.6375250+$1713.5925500+$1705.5474
-
Category: Industrial Relay/UniversalDescription: AF The series contactor, 3-pole AF contactor, is an AC/DC operated AF09-AF38 contactor that includes an electronic coil interface and can accept a wide range of control voltages Ucmin Ucmax. Only 4 coils contain control voltage of 24 → 500 V AC or 20 → 500 V DC. The AF. Z contactor is equipped with a Z coil type, allowing direct control through 24 V DC, 500 mA PLC output, which can reduce coil consumption. The AF. Z contactor can withstand short-term drops and voltage interruptions (in accordance with SEMI F47-0706). The AF40-AF96 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are designed with a block shape of 3 main poles. The AF116-AF140 contactor is mainly used to control 3-phase motors and power circuits up to 690 V AC, while the AF146 AF190-AF370 contactor is mainly used to control 3-phase motors and power circuits up to 1000 V AC. These contactors are designed in a block shape with 3 main poles. The AF contactor has built-in surge protection and does not require any additional surge suppressors. Standard IEC 60947-1/60947-4-7 and EN 60947-1/60947-4-1. ABB AF series90151+$1246.030510+$1234.703025+$1229.039250+$1223.3754100+$1217.7116150+$1212.0479250+$1206.3841500+$1200.7203